LM300 Series OIL LEVEL MAINTAINER
LM300 SERIES

The LM300 Series Level Maintainer automatically adds oil to the crankcase as needed to keep the lube level normal.

Most models have built-in switches that will alarm and/or shut down the equipment if the makeup supply is depleted and engine oil level falls or if overfill conditions exist.
 
The LM300 can be used in engines, compressors, pumps, and coolers. 

LM300 Series EX models (explosion-proof) are CSA certified for Class I, Division 1 Hazardous areas.


  • LM300 : Level Maintainer only (no switches).
  • LM301 : Low switch contacts for low-level shutdown or alarm. Four wires, SPDT.
  • LM302 : Two switches for low and high-level shutdown or alarm. Four wires, DPST, wired N.O. in normal operating ranges.
  • LM303 : Two switches for low and high-level shutdown or alarm. Four wires, DPST, wired N.C. in normal operating ranges.
  • LM304 : Two switches. Alarm before shutdown on low level and shutdown on low-low level. Four wires, DPST, wired N.O. in normal operating ranges.
  • LM305 : Two switches. Alarm before shutdown on low level and shutdown on low-low level. Four wires, DPST, wired N.C. in normal operating ranges.

Specifications: 
  • Case/Cover: Die cast aluminium
  • Switch Housing: Aluminium
  • Approval Rating: All CSA Certified with switch contacts rated at 10 A at 250 VAC (standard)
    • LM301 through LM305: CSA certified for non-hazardous locations. Enclosure Type 4 certified
    • LM301-EX through LM305-EX: CSA certified for Class I, Groups C and D; Class II, Groups F and G hazardous locations. Enclosure Type 4 certified.
  • Float: Rigid polyurethane foam; Polyurethane coated
  • Max. Ambient Temperature: 250° F (121° C)
  • Oil Inlet Connection: Top entry 1/2-14 NPT with built-in filter screen (removable for cleaning)
  • Inlet Orifices: 1/4 in. (6 mm) standard; 1/8 in. (3 mm) available
  • Wire (switch models): 18 AWG x 13 in. (1.0 mm2 x 330 mm) 
  • Max. Inlet Pressure (MIP):
    • 30 psi (207 kPa) [2.07 bar] with 1/8 in. (3 mm) orifice
    • 15 ft oil (4.6 m oil) with 1/4 in. (6 mm) orifice
  • Max. Differential: 2 in. (51 mm) between running and stationary oil level
  • Max. Case Pressure (MCP): 15 psi (103 kPa) [1.03 bar] 
  • Orifice Seal: Buna-N 
  • Thumb-Valve Switch Contact: Silver, SPDT snap-acting, rated at 10 A @ 125, 250 VAC; 10 A @ 30 VDC (1 only for low level; 2 only for high and low; or 2 only for low level with alarm before shutdown)
  • Outlet Connection: 3/4-14 NPT left side, right side and bottom.
  • Crankcase Balance Vent Fitting: 1/2-14 NPT
  • Mounting: Accepts Murphy pipe or universal mounting brackets
  • Lens: Clear Frog Eye non-staining, high-impact, high-temperature nylon; UV and heat-stabilized
  • Glass Lens: Available on LM301 and LM301-EX models. Specify GL as part of the model number when ordering.
  • Dial: High visibility white background with green and white index lines for normal level indication
  • Test Knob: Rotate to test switch operation. Turn clockwise for low-level tests and turn counterclockwise for high-level tests.



Product Original Page


Oil level warning and alarm devices, Liquid level warning devices, Oil level alarm switches, Oil level adjusters, Oil level indicators, LM500, liquid level alarm devices, Liquid level warning and alarm devices, LM300, level switch, Oil Sump level, oil condition, Automatic oil fill , Generator, liquid level indicator, Engine cooling systems, expansion tanks, Buoy, level switch, level alarm, Adjustable limit switch, oil add sensor, engine auto oil, engine oil level, oil sensor, oil low level warning, oil level sensor, oil level, oil level protector, vapor phase systems, condenser radiator, oil feed, oil level warning, automatic oil top-up, auto oil, pressurized systems, oil warning, Complementing the missing oil, oil top up,